Our Services
Our Services
Provide total power backup solution with optimization of Energy, Space, Facility cost & break-free operations along with
connecting in single calls to get service in all over India.

UPS AMC
AMC – Comprehensive
1. Comprehensive :
Newtrick Power solutio being a customer-oriented company offers comprehensive UPS AMC and battery service solutions that are designed to improve costs, uptime, reliability, power quality, and safety. Our Service Include UPS Installation and Commissioning, Battery Replacement, Battery Testing and Maintenance, UPS Maintenance and Service Contracts, Project Management, and Warranty Upgrades. With the network of highly experienced contractors and back-to-back partners, we can support clients in Major cities like Bangalore, Hyderabad, Mumbai, Delhi & almost all around India.
We are maintaining more than 1200+ UPS of various make and 300+ Customers in PAN India with the highest Service Appreciation letters from customers.
To reach every site we have a tie-up of the same level of business partners for North and East India and For West – South India we have Direct service centers across.
We provide a central point of contact for the service call logging process which helps to reduce multiple people calling for a single call.
We are not only the service providers but for implementation and root cost analysis, facility in-house and on-site technical experts to provide you solutions for whatever the issue inside or outside of UPS- which helps to reduce repeated failures.
“ Our main objective in AMC is to maintain maximum UPS uptime by using expert and well-trained engineers along with spares and standby UPS ”
Annual Maintenance Contract for Personal Home UPS and Corporates provides peace of mind to the customer as the service contract covers Quarterly PMs (Preventive Maintenance) and unlimited breakdown calls during the contract period. Any replacement of spares is free of cost during the contract period which excludes batteries, Switch Gear and Wound Components.
SCOPE OF WORK
- GUARANTEED 2-HOUR ON-SITE RESPONSE, 6 DAYS/WEEK, 8 HOURS/DAY, WITHIN 50 KMS OF A GLOBAL SERVICES’ SERVICE CENTER
- INCLUDES 100% SPARE PARTS (EXCEPT BATTERIES & WIRE WOUND COMPONENTS) & UNLIMITED BREAK DOWN CALLS
- INCLUDES 100% LABOR AND TRAVEL COVERAGE 6 DAYS/WEEK, 8 HOURS/DAY
- INCLUDES FOUR PRE-SCHEDULED QUARTERLY PREVENTIVE MAINTENANCE SERVICE.(EXCLUDING NATIONAL HOLIDAY).
- IF UPS IS NOT REPAIRABLE NEWTRICK SHALL SUPPORT BY STANDBY UPS TILL THE LAST DATE OF AMC PERIOD
- STANDBY WILL BE PROVIDED IF THE UPS CAN’T BE REPAIRED WITHIN 24 HOURS
On Call UPS repairing
1. Non-comprehensive Annual Maintenance Contract :
The Non-Comprehensive Annual Maintenance Contract provides the customer the same benefits as Comprehensive Annual Maintenance Contract when it comes to regarding Quarterly PMs (Preventive Maintenance) and unlimited breakdown calls during the contract period but any replacement of spares are chargeable during the contract period.

Repair Services :
UPS are complicated machines and not everyone is tech-savvy enough to fix these problems themselves. So, to fix the UPS problems that come in all shapes and sizes one needs experts. Newtrick Power Solution being the premium channel partner for Numeric UPS can help you with the fastest solution-based repairing for Numeric & Hitachi UPS along with that we have partners all over India who have tied up with various make such as Vertiv Emerson, APC, and Eaton along with many more which gives us access to all and any make of UPS spares which are needed, we also provide rental stand by UPS & batteries along with all the services you would ever need for your device so that no matter what the customers uptime remains good.
We have trained professionals who will give render free estimates and diagnostics in case for you to understand which service to prioritize which helps in the decision making to whether go for repairing or buy a new UPS. We also offer home services for your UPS maintenance with the professional repair of the devices being quality control as our trademark and top priority. We have successfully repaired 200+ UPS with a simplified & competitive price structure. with all this, you can rest assured that your device is in safe hands.

Power Quality Audits
What is a power audit?
A Power Audit is a systematic survey of all electrical equipment, circuits and connections in your building. It provides the foundations for a future-proofed power protection system and can help you reduce your energy consumption.
Why there is need of power quality audit?
Conducting a Power Quality Audit will identify the issues that are causing poor power quality in your business. A Power Quality Audit can provide the data that is required to design an appropriate solution to tackle the issues.
The problems that may arise
The most common disservice of a not fully reliable electrical system is a break in the power supply: either complete breaks,lasting from a few seconds to several hours, or voltage sags/drops, when the voltage falls to below the rated level for short times.Longer breaks are a problem for all users,but many processes, such as continuous and synchronised production processes or high-value data processing, are sensitive to even the shortest of breaks.Other disturbances that may occur are: over voltages, harmonic distortions,imbalances, reduction of power factor etc. Ignoring the symptoms of possible disturbances in the electrical system could lead to damaged equipment, consequently reducing its working efficiency and shortening the life span. The resulting break in critical processes (i.e. machine downtime) could lead to a loss of earnings that could far outweigh the mere cost of the actual operation.In addition, there is also the likely risk of having to bear increased energy costs and pay penalty charges in electricity bills,with the possibility of legal disputes with energy providers.
How can we help and what can we do?
we provides a complete picture of the electrical system’s correct state of operation. The report which we provide is a tool of primary importance for preventive maintenance, in that we list all the measures to be taken promptly when disturbances are detected, before the negative impact on production and the running of the equipment is felt.
PROCESS OF P.Q.A (Power Quality Audit)
- Program start-up & orientation of site
- Onsite Assessment of electrical site
- Data collection from various location to thoroughly understand the site
- Final report preparation by professionals by thoroughly understanding weak and strong points
- Submission & Presentation of report
- Presentation of products & Solutions Along with application Guide & Notes
Energy Audits
Our main objective and focus for energy audits is on conserving energy and reducing carbon and environmental footprints. We would collect, inspect and analyze the energy flow and collect this data to make strategies to reduce energy consumption in buildings.
SCOPE OF WORK
- Calculating the amount of energy conservation
- Identifying any health or safety concerns that may arise as a result of the planned welfare projects

- Collecting and evaluating energy usage information from various sources
- Determining which energy-saving solutions are considerable
- Setting standards for energy use or need by monitoring energy consumption
- Determining the energy consumption of each system by inspecting or evaluating construction methods, mechanical systems, electrical wiring, or process systems
- Preparing audit reports that include the results of the energy analysis or suggestions regarding energy cost savings
- Examining energy bills along with utility rates or tariffs to collect past energy consumption data
- Understanding technical feasibility of energy-saving measures using engineering knowledge, energy use, construction, maintenance, system operation or process systems
- Recommending customers on energy efficiency and how to choose energy-efficient appliances
- Overseeing the installation of energy-saving equipment such as water heater wraps, pipe insulation, door sweeps and low-flow showerheads

Free Battery Health Checkup
Thermal Audit for Electrical
We are engaged in providing our clients Electrical Thermography or Thermal Audit By Qualified Professionals. An infrared electrical inspection can minimize injury, liability, damage, catastrophic failures and downtime of the organization,
Many conventional electrical problems have unconventional answers, which are not revealed in routine inspection. Small faults may be negligible but could create lasting damaging effects to life & property in the long run.In electrical systems component’s age, fatigue, oxidation, wear & tear, loose connections , poor installation can increase resistance & heat .
Infrared cameras catch this heat. This is why an Infrared electrical inspection is the best way to detect early electrical failures, because most electrical things tend to get hot before they fail) IR Inspection mainly involves scanning, image taking and image analysis and among them analysis part is most important for correct diagnosis of problems.
Thermal Audit can detect many problems in many electrical systems such as following :
- Switchgear in organization and substations
- Transformers
- Power transmission lines
- Determining which energy-saving solutions are considerable
- Distribution panels, circuit breakers and conductors
- Computer and low voltage systems
- Machine control Panels
- PLCs (Valves & Relays)
Advantages of Thermal Audit:
- Infrared Thermal imaging can help you detect problems like inductive heating, hot bus bar ,overloaded circuit & many undesirable electrical situations
- It can be used to measure or observe in areas inaccessible or hazardous for other methods
- It is a non-destructive test & contact free method
- Thermography inspect electrical objects in dark areas
- Distribution panels, circuit breakers and conductors
- An Infrared inspection can immediately detect an overheated wire in the mesh of wires and terminals, which is impossible to see with naked eyes.
- An infrared electrical inspection can minimize injury, liability, damage, catastrophic failures and downtime of the organization An effective preventative maintenance strategy must include an infrared scan.
Electrical equipment’s can suffer from numerous faults which will show and increase in temperature:
- Corroded or loose connections
- Imbalanced Loads
- Using underrated equipment or overloading equipment
- Insulation Damage
- Incorrect voltage
- Blocked or poorly ventilated equipment
- Deterioration due to age
- Exceeding the recommended temperature rating
The electrical equipment’s which are surveyed would include:
- Motors and motor control panels
- Control equipment
- Cable runs
- Substations
- Transformers
- Circuit operating devices
- Thyristor banks
- Switches, fuses and circuit breakers
- Distribution boards
Scope of work:
We shall cover the following under scope of work for Thermal audit:
- We will carry out the Thermography under full load condition Online.
- We shall remove the doors & covers of the Main DB’s LT Panels & Sub-distribution panels.
- The real Image & Thermal Image of each switch-gear will be recorded for any temperature variation.
- If there is any abnormal temperature rise, then the parameters like rating of switchgear & cables & cooling system/ventilation will be evaluated
- The peak & RMS current flowing through the conductor/switchgear.
- If any loose connections/corrosion of contacts is found, the same shall be mentioned in the report for further corrective action.
- This one activity is treated as one electrical point.
- The time required for conducting this process is @30-45 min depending on the location & accessibility.
We shall carry out this process for LT room, DG room & DG working on DG mode, Change-over panel, Main incoming Transformer & its Switch-gears (is carried out at evenings after sunset). Floor-wise distribution panel (If required).
On-Call Battery Maintenance
Every UPS (uninterruptible power supply) system has a battery that initiates when loss of power from the main-source is identified. The battery is the life behind every UPS system. The UPS battery acts as a secondary power source that allows data to be saved in the event of a commercial power outage. Unfortunately, the battery is the weakest link in every UPS system. UPS batteries should be properly maintained and monitored to prolong their life, mitigate safety concerns, and most importantly, avoid downtime. Follow this simple guide below to learn the importance of battery maintenance and monitoring and understand how to perform these tasks effectively.

UPS Placement, Temperature and Environment
The environment around the UPS plays an important role in battery performance and life expectancy. Batteries cannot function properly in temperatures that are too hot or too cold. The temperature recommendation from the battery manufacturer should be followed stringently. Most UPS batteries designed to operate at an ambient temperature of 77°F. If a battery is operated at higher temperatures, its usable life will be shortened significantly. Too cold and the batteries performance will be decreased. New technologies such as lithium-ion and TPPL can operate at higher/ lower temperatures but most UPS batteries are conventional Flooded or VRLA and are designed for 77°F.
It is also important to note that the UPS should not be placed near open windows, corrosive fumes, dust, or anywhere with moisture.
Determining Battery Life Expectancy
Most UPS batteries do not last as long as the battery manufacturer suggests. Many factors play a role in battery life. UPS battery do more than just provide power during a power outage. They are constantly called upon for line conditioning. This means that regardless of the quality of your commercial power service, computers, servers and data will always receive clean pure A/C power. UPS batteries may be called upon many times per day, this is known as cycling. A cycling monitor attached to your UPS battery can be a valuable tool in predicting “end of life”. Using a cycling monitor for UPS batteries will allow data center staff to plan for battery replacements before it’s too late, therefore avoiding costly downtime.
Maintain UPS Batteries’ Float Voltage Through Regular Maintenance
Another crucial item in battery performance is float voltage. The battery manufacturer provides the proper float voltage, usually 2.25 to 2.27 volts per cell. The battery’s voltage should be routinely monitored and adjusted as needed. Over charging a battery will lead to premature failure, undercharging will reduce its performance and can also cause premature failure.
UPS Battery Maintenance
“Maintenance-free” UPS batteries do not require replacement fluid, but they do require periodic maintenance. Battery service and maintenance are essential to ensuring ongoing UPS reliability. Without it, a UPS battery becomes susceptible to a number of threats that can ultimately result in a reduced level of protection and premature failure. Visually inspect batteries for cleanliness and remove any dust, dirt, or debris. Leaking batteries or batteries with excessive swelling are a sign of “end of life” and should be properly disposed of and replaced.
Proper maintenance allows the end of battery life to be accurately estimated, enabling scheduled replacement without unexpected downtime or loss of backup power. In addition, preventive maintenance helps extend the life of battery strings, providing the opportunity to detect loose connections, remove corrosion and isolate bad batteries before they affect the entire string. Finally, gradual decreases in battery life can be monitored and evaluated through periodic voltage assessments and load testing completed during a PM visit.
During regularly scheduled PM visits, trained technicians should perform a number of inspections, including visually scrutinizing batteries, racks or cabinets for signs of corrosion and leakage; measuring the float voltage and current of the entire bank; recording the terminal voltage of all cells; checking the electrolyte levels and specific gravity readings in each cell (for flooded batteries only); noting the ambient temperature; conductance or impedance readings should be taken from every cell and compared to the manufacturer’s published values. All readings should be archived for comparison with future readings.
IEEE Standards: UPS Battery Maintenance, Monitoring and Testing
The Institute for Electrical and Electronics Engineers (IEEE) is widely accepted as offering the best standards-driven recommendations to those responsible for battery maintenance procedures. IEEE guidance encompasses inspections, measurements and capacity tests. Refer to the following standards for more information regarding battery maintenance: IEEE 450 for vented lead-acid batteries (VLA), IEEE 1188 for valve-regulated lead-acid batteries (VRLA), and IEEE 1106 for nickel-cadmium batteries (NiCad).
Battery Storage
To avoid the consequences of downtime, many UPS owners may purchase replacement batteries before they’re needed. Traditional lead acid batteries MUST be charged every six months or they will suffer a permanent loss of capacity. The battery manufacturer will provide the proper charging sequence. Proper charging procedures must be followed to ensure the battery warranty remains valid.
Supplemental Battery Monitoring Technology
Remote battery monitoring technology is available from a variety of manufacturers that can assist a technician with routine maintenance. These systems can send notifications when alarm thresholds are reached. Systems can monitor float voltage, cell voltage, electrolyte levels, internal conductance/ resistance and more. While remote technology cannot replace the need for routine visits, it is an additional tool that can help assure maximum protection (up time) and predict battery end-of life.